Welcome to Sunderland Engineering

Your Solution to:

ENGINEERED SPCC PLANS -We Guarantee Our Work
  - A better value than others (Ag Compliance Group)
 SELF CERTIFIED SPCC PLANS- at a discounted rate

FUEL CONTAINMENT & SPCC:
    -Farm SPCC applies to anyone with one (1) or more 10,000 gallon tank(s); or 42,000 gallons or more total capacity.
    -NON-Farm SPCC applies to anyone with 1,320 gallons or more total capacity.

Our Services:
    -Site Planning & Facility Arrangements
    -Engineered Secondary Containment systems that meet United States EPA requirements are designed & built for clients.
    -Building Codes, Fire Codes, Local Codes      
    -Secondary Containment Construction Materials
            -Fuel & Oil Product Containment
            -Liquid Fertilizer Containment
    -Construction Crews for Containment Installation
    -Get The Job Done Right, The First Time
 

SPCC PLAN DEVELOPMENT:
    -Certified SPCC Plans Are Created To Fit Each Client,          and Certified BY a Licensed Engineer
    -Self Certified SPCC Plans Are Also Developed
    -Elements Of A SPCC Plan, Include...  

  • Facility diagram and description of the facility
  • Oil discharge predictions
  • Appropriate secondary containment
  • Facility drainage
  • Site security
  • Facility inspections
  • Requirements for bulk storage containers

SECONDAY CONTAINMENT FOR LIQUID FERTILIZER and PERMITTING:
    -We Assist Farm Producers With Applying to MDA for On-Farm Liquid Fertilizer Storage.
    -We Assist Chemical Distributors With Applying to MDA for Fertilizer & Chemical Storage.
    - Engineered Secondary Containment systems that meet Minnesota Dept Of Agriculture requirements are designed & built for clients.

Permits & Secondary Containment Apply To Farms That: 

  • Farms That Store More Than                            6,000 Gallons Of Liquid Fertilizer At One Time (effective since 7/1/07)

CHEMICAL WAREHOUSE DESIGN:
-Designs For Ag Cooperatives and Agricultural Suppliers
-Load Pad/Loading Areas for Bulk Pesticide Transfer
-Concrete Design, and Construction Specifications
-Complete Permit Application Consulting
-Design Meeting Minnesota Department Of Agriculture Rules
 

CONCRETE FOOTING DESIGN:
-Footing Design and Specification
-Wood and Steel Structure Supports
 

Poly Fuel Containment Totes Below:

Learn More

WE ARE YOUR DURALIFE
ON-FARM SECONDARY CONTAINMENT
DEALER FOR
-FUEL &
-LIQUID FERTILZER

~ ~ ~ ~
POLY SECONDARY CONTAINMENT:
POLY TOTES
-Durable
-Light Weight
-Easy To Move
-EPA Compliant

TOTE TYPE 1:
Fits (2)- 1,000 Gal
or (2)- 560 Gal
or a combination
8'X14'X2' DEEP

TOTE TYPE 2:
Fits(1) 1000 GALLON
or smaller tank
Future Expansion
6'x8'x38'' DEEP

TOTE TYPE 3:
Fits(1) 2000 GALLON
or a combination of smaller tanks
Future Expansion
6'x16'x38'' DEEP

See Bottom Of This Page... 

Find out more